logo
Un bon prix.  en ligne

Détails des produits

Created with Pixso. Maison Created with Pixso. Produits Created with Pixso.
Surveillance multiparamétrique de la qualité de l'eau
Created with Pixso.

Micro Water Quality Monitoring Station Multi-parameter pH ORP Turbidity DO Monitor Solar Power For Lake River

Micro Water Quality Monitoring Station Multi-parameter pH ORP Turbidity DO Monitor Solar Power For Lake River

Nom De Marque: JUGE
Numéro De Modèle: AG-SZ05
Nombre De Pièces: 1 Unit
Prix: USD1000-5000
Détails De L'emballage: Neutral carton
Conditions De Paiement: Online order,T/T
Informations détaillées
Place of Origin:
Nanjing, China
Certification:
IOS9001, CE
Name:
Micro Water Quality Monitoring Station
Parameter:
OEM
‌Signal Output‌:
RS485
Installation‌:
Outdoor
Power supply:
AC or Solar power
Sampling:
Floating sampling
Dimensions‌:
1480×800×625 mm
Weight‌:
60 kg
Supply Ability:
100 Unit/Week
Description du produit

Micro Water Quality Monitoring Station Multi-parameter pH ORP Turbidity DO Monitor Solar Power For Lake River


>>Overview

The micro water quality monitoring station is based on measurement principles such as optics and electrochemistry, and can monitor parameters such as temperature, pH value, conductivity, turbidity, dissolved oxygen, COD, ammonia nitrogen, etc.

Display    7 "color touch screen, Chinese and English operation interface, easy to operate

Data storage  Data storage, viewing, and exporting functions, with customizable storage periods

Output a: 1 RS485 Modbus RTU standard protocol;

b: 2-channel switch, program controlled output (can control self-priming pump, automatic cleaning)

c: 5-way 4-20mA program setting output (optional)

d: Standard wireless 4G upload

Password Protection Password protected correction data to prevent non professionals from making mistakes

Power supply  220VAC


>>Feature

● Integrated design, applicable to different scenarios, can be matched with different monitoring factors according to different scenarios. Suitable for outdoor places such as lakes, reservoirs, rivers, wetland parks, etc;

Small size (0.5m2), small footprint, comprehensive configuration, and good mobility;

Outdoor installation, directly place;

● Adopting a modular outdoor chassis specification design and modular analysis unit, it has strong environmental adaptability and is easy to expand;

High integration, simple system flow, easy equipment maintenance and operation;

● Equipped with an industrial computer system that complies with the technical specifications for automatic monitoring of surface water;

Compatible with multiple communication modes;

Floating water sampling;

IP67.


>>Floating Sampling

The mobile float type water collection system consists of a water collection pump, a front-end spring filter screen, a float, a fixed anchor or cement pier, and a cable.

The mobile float type water collection scheme is suitable for sites with large water level changes, wide areas, and steep banks in the watershed. The movable float type water extraction scheme can make the float float float up and down with certain water level changes, and at the same time, it can move horizontally to a certain extent. In this way, it can ensure that the water collection outlet is located 0.5-1.0m below the water surface and can collect water samples during the dry season of the river. The horizontal movement can improve the reliability and safety of water collection to a certain extent, preventing damage caused by collisions with external objects.

The float is designed in a circular or streamlined shape to reduce the impact of water flow and avoid the attachment and entanglement of floating objects and weeds in the river.


Feature:

▪   The material of the float is high molecular weight polyethylene, which has the advantages of sealing, thickness, acid resistance, alkali resistance, and antifreeze.

▪   The filtering device is made of high-strength and finely spaced stainless steel material, which can provide good filtering effect and prevent blockage of the water collection pump.

▪   According to the on-site situation, the water collection pump adopts a submersible pump, and the water collection pipeline adopts high-quality UPVC pipes. The control system is equipped with the function of automatically diagnosing the fault operation of the sampling pump.

▪   Manual and electric ball valves are installed at the end of the water collection pipeline. By controlling the valves, the water collection flow rate and pipeline cleaning can be adjusted.

▪   The rubber hose and UPVC pipeline at the front end of the water collection are covered with high-quality insulation material rubber sponge, which can provide thermal insulation and prevent the water collection pipeline from freezing. For project sites in extremely cold environments, a heat tracing strip is wrapped around the periphery of the water collection pipeline to provide heat tracing during the cold winter season, protecting the water collection pipeline from freezing damage.


>>Technical Parameter

Item

Index

Item

Index

pH

         Dissolved oxygen

Principle

Glass electrode method

Principle

Fluorescence optical technology

Range

0~14 pH

Range

0~20mg/L

Accuracy

± 0.1pH

Accuracy

± 0.3mg/L

Resolution

0.01pH

Resolution

0.01mg/L

MTBF

≥1440H

MTBF

≥1440H

Conductivity

Turbidity

Principle

4 pole electrode method

Principle

90° scattered light+140 °transmitted light

Range

0~500ms/cm Auto switch

Range

0~4000NTU

Accuracy

± 0.5%

Accuracy

± 5%

Resolution

0.01/0.1

Resolution

0.01/0.1

COD(COD/TOC/BOD)

Ammonia nitrogen

Principle

Ultraviolet fluorescence

Principle

ISE

Range

0~500mg/L

Range

0~1000mg/L

Accuracy

± 5%

Accuracy

± 5%

Resolution

0.1/1

Resolution

0.1/1

Nitrite/Nitrate

ORP

Principle

ISE

Principle

Potential method

Range

0~1000mg/L

Range

±2000mv

Accuracy

± 2.5%

Accuracy

± 3mv

Resolution

0.01/0.1

Resolution

0.01/0.1

Temperature

Principle

thermal resistance

Accuracy

±0.2℃

Range

0℃~60℃

MTBF

≥1440H


>>Application

Micro Water Quality Monitoring Station Multi-parameter pH ORP Turbidity DO Monitor Solar Power For Lake River 0